Email: service@parnassusdata.com 7 x 24 online support!
Oracle ORA-600 [kccpb_sanity_check_2]
VERSIONS:
Versions 10.2 to 11.2
DESCRIPTION:
This internal error is raised when the sequence number (seq#) of the
current block of the controlfile is greater than the seq# in the controlfile header.
The header value should always be equal to, or greater than the value
held in the control file block(s).
This extra check was introduced in Oracle 10gR2 to detect lost writes
or stale reads to the header.
ARGUMENTS:
Arg [a] seq# in control block header.
Arg [b] seq# in the control file header.
Arg [c]
FUNCTIONALITY:
Kernel Cache layer Control file component.
IMPACT:
INSTANCE FAILURE
PROCESS FAILURE
POSSIBLE CONTROLFILE CORRUPTION